Partially loosen the screw that holds the "off" pin in place. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. During this the pump cannot be manually switched on. Black goes to _1 If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Also, does it sound like the power is not leaving the breaker? I also dont see any ants or other insects. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. Things are working fine and all of a sudden the pool pump did not start in the morning. Hi Rich, is one of those wires (white?) But no gears or any sound. Or be loose and not making good contact. The pool timers I have had down there . Thank you. The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. DEWENWILS Outdoor Outlet Box. Repeat the process for the "on" pin. You need that 8 hr run in just the summer . Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. I currently manually turn it on and off. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. However, since I did that the time clock stopped working I looked at the motor visual window and nothing is moving. You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. it could also be a failing breaker, but that would be a last resort. The gears in mechanical timers can get damaged. Is it Necessary? Or may be bent and not come together. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Wont work manually or by timer function. However the new breaker is in a constantly tripped position. Today is the second day that I have had to turn it on manually. The A terminal is not normally used, unless you have a 3 wire service. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Or there could be a bad relay in the control panel, if you have ice cube style relays. Any suggestions as to how to test clock feed? Any guidance on how to fix this? Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. Ordered new ones. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. A timer that switches on and off at the wrong times usually occurs after a power outage. Not two OFF trippers? I had a thunderstorm last night and my power went off for like 3 hours. i would like to use a timer but am now afraid to try another. {
I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. NEW CONSTRUCTION. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. "caption": "In The Swim Blog"
TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. The rest of your setup is probably fine. AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. Until it came in, I manually turned on and the tripper turned it off. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. If power is coming to the timer motor, you will clearly see the gears moving through the small window. It started lagging again a week or so ago. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. Check the motor, and be sure the label is not printed 50 hz. I bought a new timer and replace the T104 timer clock. The trippers will "trip" the analog clock to turn on and off automatically at the set times. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting did i do something incorrectly? With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. Hello. Check that dial is not warped. Could also be grit or insects inside of the gears of the clock motor. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. Flip off the breaker. If not, the motor may be failing. The pump worked perfectly before I unscrewed it. },
The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveler reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. As an Amazon Associate we earn from qualifying purchases. what causes timer on/off pins to bend and how can i prevent timer pins from bending. Should it still not work, I suspect a motor failure for the clock. You will have live wires exposed and they can kill you if you touch them. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. Or fold the cover to one side if needed. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Or might find something else. You can check these easily by removing them and inspecting them for damage. It sounds like the Line and Load wires are reversed. "url": "https://intheswim.com/",
HI Jeff, do you have power outages sometimes? Then remove the mechanism by pressing the clip at the top of the timer box. Reference Manual & Buyer's Guide Another Brick in the Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. Hi Carlos, is there a GFCI outlet in the circuit? IT happens, so I ask. Go for it, a little maintenance expense. No broken or loose wires visible. Is there anything else I can do or do I need to get a new one? Hi. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! I hope this helps. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. Wont power on pump but can hear timer clicking away. View community ranking In the Top 5% of largest communities on Reddit. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. For additional tripper pairs on CLOCK-DIALorder 156T1978A. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. Ive reset the time 5 times and just realized that its going counter clockwise. Theres an issue with the wiring between the circuit breaker and the timer. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. "@type": "ImageObject",
May we present Speed Tripper, the second pedal collaboration from Death By Audio and LEVITATION. Jul 20, 2021. Does this mean I need a new T104, or is there a replacement manual on/off switch? Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . Any help is greatly appreciated. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). My pump has a plug. What do you suggest to do to get the cover up and the pillows back into position. It I set the timer again it will jeep time until it gets to the next dog ear. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. If its not, it wont work properly. It is an ON tripper right? You may need to adjust the meshing of the timer motor gear so it runs the clock. View more property details, sales history and Zestimate data on Zillow. The position of the metal bar forces the gear next to it to turn one way or another. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Rich. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. If it doesnt, there could be an issue with the clock face or gears. Pop-in a new timer mechanism, and replace the wires to the previous configuration. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. Please advise. Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. Also known as an RCD (residual current device) in Australia and the UK. You can replace it but its really just easier to replace the entire mechanism. Look to see if the clock is set to the correct time. 2,767 Sq. Does the manual lever stay in the on position always? Only perform this step if you are qualified. Advice? There could also be other mechanical reasons for this happening, such as a disconnect in the switch. Start with the easy checks. Pools are not cheap! Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. Other causes include rusted springs, insect infestation and loose timer dogs. The mechanism for the off tripper doesn't work at all when manually depressed. For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. The yellow clock face should sit down in the timer. A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. we purchased the house 5 years ago so not sure how old the timer is? I have a 2 speed pump. Assuming the wiring is all correct. The clock is powered from the Line 1 terminal correct? I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. For Do-it-Yourself pool owners like yourself to make simple,, Sure, you could just replace your entire Hayward pump, but replacing only the motor is just as easy, and you don't have, Millivolt Pool Heater Troubleshooting Guide, https://www.intheswim.com/p/2-circuit-pool-timer, https://www.intheswim.com/p/24-hour-pump-timer, https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf. Thank you so much. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. },
Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. I bought a new motor for mine after 20 years and learned about this the hard way. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. The problem lies, where the power dies, as they say, Thanks for the response. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. You should always be able to switch your pump on and off manually at the timer. The circuit is protected by two ganged breakers. It could also be loose wires, either on the time clock terminal board, or on the timer motor. Replaced complete new timer assuming 5 years perfect service probably wore it out. Hi there, Paul, it could be that you got a 50hz motor, instead of a 60hz? When you flip the switch does it separate and reconnect the tabs? First, verify the power is turned off at the breaker panel. Tighten down all brass screws securely, to hold all wires firmly in place. "keywords": "",
Pool timers can also be used to automatically turn on/off pool lights or other outdoor lighting around the pool. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
3 Baths. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. Does the tripper work on other areas of the clock, like near the off tripper? I have the PF1202T timer on my pool. Push the tab on the top, and let the mechanism fall forward. If I manually push the lever, it moves without much pressure. Pool pump comes on fine with the on dog, but wont turn off. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. sometimes Im forgetful lol what are your thoughts? I have the Intermatic T103 autotimer on my pool. And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. First, you need to set the time, which is good to know in case of a power outage, or daylight savings adjustments. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. do i need to do something different? 120Volt Tork 1101 timers can be fixed with repair parts. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. "width": "611",
It just stays at that time. Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. If its loose, grab a screwdriver and tighten it up. Take them off and inspect them and look for twists in them. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? If its not, then the timer will not turn on/off at the correct times. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. I am using the breaker to turn on and off the pool pump. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. Hi, I got the same problem as my clock not working. Still no luck. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. That will do it. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. },
My timer clock does not run and the manual on off switch does not turn off the pump motor. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point.