Thanks. Does the 3 foot distance apply to all equipment or just the heater and generator? Southern California Edison Unit Cost Guide dated March 30, 2019 . PG&E says we are responsible but it's not even near our house! But it is a reasonable concern. My question being, is it ok for the electrical conduit to pass by the gas line so that I can then bury the electrical conduit 12" below the gas line that will be more superficial to the surface, or are the lines not allowed to pass each other that way? How far from gas supply line to. Please note that building opening means Inasmuch as the meter and electrical panel are completely separated by the noted wall, are there any minimum clearance regulations that apply? If the hand is between two numbers, always select the lower number. GR Sheet 2 RESIDENTIAL SERVICE (Includes GR, GR-C and GT-R Rates) (Continued) (Continued) (TO BE INSERTED BY UTILITY) ISSUED BY (TO BE INSERTED BY CAL. From the page above we know that A lady just bought abandoned house next door. "The National Fuel Gas Code Handbook," in its discussion of the above cited gas meter clearance, states that electric meters (except those that incorporate switching relays) are not considered a source of ignition. The comment below would not let me post two images. I read at https://inspectapedia.com/plumbing/Gas_Meter_Clearances.php that Gas Meters should be two feet in any direction from exterior hose bibbs. The clearances for many other types of building features and landscape features are also included. In addition, you and your neighbour should review GAS METER PROTECTION BOLLARDS This rate is calculated by the day so you would take whichever one is applicable to you and multiply it by the days in the meter read cycle. Temperature compensation available from -30F to 140F. There are a lot of violations of this in Northern New Mexico. A gasfitter sizes a rotary gas meter depending on the gas volume flow rate. Access shall be provided to pressure regulators. Questions have been asked regarding the specific types of electrical equipment covered by the Rule. Is this dangerous?. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References, Defects, installation & inspection points for gas meters. Submit an application for non-residential new construction if you need to establish natural gas service by installing new pipeline and/ or meter(s) to a non-residential construction site that did not have prior service, or to re-establish natural gas service by installing pipeline and/or meter(s) to a structure that was demolished and will be rebuilt. I would like to install a Generator and Pool Equipment near by existing gas meter. All rights reserved. Similar to what many gas provider companies install - one piece body with security seals to indicate tampering. Sure, the clearances are given in the article above. https://inspectapedia.com/plumbing/Electrical-Arc-to-Gas-Equipment-Distances-Ontario.pdf Arc-producing electrical equipment which is considered a source of ignition includes, but is not limited to: That's not a specification that I've been able to find, John. @Joe Sirianni, Schedule G-NGVR, Natural Gas Service for Home Refueling of Motor Vehicles (Includes G-NGVR, G-NGVRC and GT-NGVR Rates) Schedule GL, Street and Outdoor Lighting Gas Svc; Schedule G-10, Core Commercial and Industrial Service (Includes GN-10, GN-10C and GT-10 Rates) Schedule G-AC, Core A/C Svc for Commercial/Industrial (Includes G-AC, G-ACC and GT . Santa Fe, New Mexico 87505 minimum clearances specified in this table must be maintained. 10 gallon aquariums, 5 gallon aquariums, 50 gallon aquariums and more! Originally had concerns of the functionality of the water hose directly above the gas meter. normal cubic meters (Nm3) - 1 cubic meter at 20C at 101.325 kPa. what are the clearance requirements between a gas pool heater and electric A/C unit? There's not a single generic right answer to your question as phrased. I informed her I was building a fence around our property line which begins at the wood fence area. To be conservative, 15% is added to the gas meters rated capacity to arrive at its maximum continuous capacity. Therefore for this example, the size of the meter is "U100." Sometimes, particularly in more modern meters, the first 2 or 3 digits of the serial number also indicate the meter size. Please be advised permits for construction must be secured before completing this application. Meters for commercial buildings cost $400 to more than $1200. The immediate concern I see in your photo is that you have a gas meter along a driveway where it appears from the presence of the boat that it could be struck by a vehicle and yet there are no protective bollards installed. (575) 524-6320 The baseline allocation is determined by zone and number of days in the billing cycle, much like This is a mobile home park, and our units are close together. Local building code requirements for safe distances from a gas meter or gas meter vent vary, depending on where you live, and are also different between the U.S. and Canada. This often happens when several large gas-powered appliances are being used simultaneously. Gas company informed us and her about the clearance issue for meters . TANKS, AND ELECTRIC LINES, CLEARANCE DISTANCES: ELECTRIC ARC SOURCES to GAS EQUIPMENT - ONTARIO, GREEN BOOK ELECTRIC & GAS SERVICE REQUIREMENTS, GAS METER CLEARANCES AND SERVICE INSTALLATION REQUIREMENTS, GOOD PRACTICES FOR GAS PIPING AND APPLIANCE INSTALLATIONS, GAS METER & REGULATOR CLEARANCES, CONTRACTOR GUIDELINES, HOW to READ ELECTRIC & NATURAL GAS METERS, ATCO, GAS METER CLEARANCE SPECIFICATIONS for ALBERTA, PG&E GREEN BOOK ELECTRIC & GAS SERVICE REQUIREMENTS (TD-7001M) 20202021, CLEARANCE DISTANCES FOR AIR CONDITIONER / HEAT PUMP COMPRESSOR / CONDENSER UNITS, PROTECTION BOLLARDS for MECHANICAL EQUIPMENT, ELECTRICAL WIRE CLEARANCE FROM DUCTS & PIPES, GAS REGULATORS & APPLIANCE / HEATER CONTROLS, ARTICLE INDEX to GAS APPLIANCES, PIPING, CONTROLS, HOME INSPECTION EDUCATION COURSES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES, Front wall (front presumed facing public access), or within 3 feet of side wall (see corner clearances), Regulator relief vent distance from any outside building corner, Bottom of gas line shut-off to finish grade, Fuel line connection location (at meter top) to finish grade, 32 inches to 46 inches depending on gas meter model & meter type (size or capacity), Minimum soil depth or cover over residential gas service line, Maximum soil depth or cover over gas service line, Gas meter regulator vent clearance distance to windows, attic vent, crawl space vent, soffit vent, Gas meter regulator vent clearance to electrical devices such as switches, electrical receptacles, power disconnects, Gas meter regulator vent clearance to building doors or garage doors, Heating appliance air intake or exhaust opening, Gas meter clearance distance to air conditioner or heat pump (pad mounted) compressor/condenser unit, Gas meter clearance distance to electrical generator or electrical transformer, Gas meter clearance distance to open flame barbeque or cooker or to an incinerator or other open flame device, Gas meter clearance distance to telephone, cable or other communications connection box or terminal, Gas meter clearance distance to water spigot (hose bibb), Electrical box front (face) clearance distance to gas meter, Gas meter clearance distance to SEC / Conduit, Gas meter clearance distance to electrical ground rod, Gas meter vertical clearance distance from meter top to roof overhang, soffit, deck, porch, Gas meter horizontal clearance distance from entry door above the meter (e.g. Underground gas piping shall be installed with sufficient clearance from any other underground structure to avoid contact therewith, to allow maintenance, and to protect against damage from proximity to other structures. If a mistake is made, it could be costly and time-consuming to put right. We recommend submitting this application before starting your home or commercial/industrial facility improvement project. Recognize that each dial represents a number in a 4- to 5- digit reading. A tracer wire is usually not connected directly to the meter, though it can be. A line pressure regulator shall be installed where the appliance is designed to operate at a lower pressure than the supply pressure. The following applications and cost estimator tools on SoCalGas' Builder Services page will be undergoing maintenance on Wednesday, February 1, 2023, from 5 to 7 PM PST: Application for residential new construction natural gas installation. How to determine gas meter size To establish the size of meter you require depends on two main factors: The first is the pressure in the gas mains (low or medium . My concerns are that the snow/ice may build up since there is very little room. and specifically the section on "Closest recommended clearance distances for A/C or Heat Pump Compressors". These are typical gas meter clearance distances to various building features, but keep in mind however that this list is not exhaustive. Our gas company recently replaced our meter and upon reconnecting found a leak. It also covers the piping to the outside water for his unit. A larger-flow residential gas meter may be 1-3" larger in its largest dimension than your existing one, and are typically in this range: Source: "Gas Meters for Natural or LPG Gas", PlumbingSupply.com, 994 E 20th St., Chico, CA 95928 USA retrieved 2017/07/01, original source: https://www.plumbingsupply.com/gasmeters.html. socal gas meter sizes. How close to the gas meter can i legally install a water heater? Rule No. So, for coastal areas of California, your winter baseline allocation would be 1.691 units per day * 30 days = 50.73 units for the month. Youll see a long long list of emissions products, but look again most of the contaminant levels listed are in the, apvgn.pt/documentacao/iangv_rep_part1.pdf lists the components in natural gas exhaust from vehicles, The Need Project, Manassas, VA: need.org/needpdf/infobook_activities/SecInfo/NGasS.pdf, Kroschwitz, Jacqueline I., and Mary Howe-Grant (eds.). Nov 24, 2015. Schools and nursing homes could use up to 1000 kilowatts at any given time or more. Cha c sn phm trong gi hng. Do not locate gas meter set assembly (MSA) under decks, doors or stairways 3' Electric Outlets 3' Door 3' 3' 3' 3' 3' 1' Soffit Vents Garage Doors Attic Vents Openable Windows Crawl Space or Garage Vents Appliance Vents or Air Intakes 3' Min 16" to 18" 3' 3' Relief Vent 26" to 28" Typical AC Condenser Diagram A . Southern California Gas Company - New Residential Single Meter Drawing March 2013 Page 2 NEW SINGLE METER RESIDENTIAL CONSTRUCTION (< 1 MM BTU/HR) AC Condenser 10' 48" 12" Water Heater N ote(s): 1. Electrical will be housed inside conduit. Learn More. Learn more by reading about the different construction projects below. opposite or another wall. SteveWe have collected a number of mobile home codes and standards atMOBILE HOME CODES & STANDARDS A commercial building could use much more gas. On 2021-06-29 Only one image can be added per comment but you can post as many comments, and therefore images, as you like. Thanks! We require a 3-foot minimum separation between natural gas and electric facilities. There shall be a minimum distance of 3 feet of unobstructed working space, measured from the meter face, in front of all electric and natural gas meters. 589) We're checking to see if Colorado has a different standard. or does it have to be on the out side of fence? need to run electric line from breaker box to sub panel outside to entry spot in foundation there is a gas line already there can I run the enclosed wire next to gas line what would be the min distance from gas line? Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. Its service area encompasses 23,000 sq mi (60,000 km 2) of diverse terrain throughout most of Central and Southern California, from just south of Sanger to the Mexican border. laws-lois.justice.gc.ca/eng/regulations/SOR-86-131/index.html. When the hand is between "9" and "0," then "9" is considered the lower number. CLEARANCE DISTANCES: ELECTRIC ARC SOURCES to GAS EQUIPMENT - ONTARIO [PDF] in Ontario Electrical Safety Code, Bulletin 2-10-13 Electrical equipment near combustible gas equipment Rule 2-326 and 6-408 (2019) retrieved 2021/09/23 original source: https://esasafe.com/assets/files/esasafe/pdf/Electrical_Safety_Products/Bulletins/2-10-13.pdf Does anyone know when the 3' clearance from a "Gas meter regulator vent clearance to electrical devices such as switches, electrical receptacles, power disconnects" (and electric utility meters) came into effect? When the generator is in use, it is connected to a natural gas hose with a regulator inline that automatically stops the gas when the engine stops. In summary, the three-foot clearance cited in the National Fuel Gas Code is not directly applicable to the clearance between gas and electric utility meters." I only have two appliances using gas. In Diaphragm Meter by Itron, Honeywell Elster Turbine Flowmeter, Measurement and Control of Natural Gas, Rotary Gas Meter. Please do take a look. In addition to the gas meter clearance distances given in the page above, tell us who and where "DTE" is, (your country and city of location might help), and let's see if we can find DTE's own specifications for gas meter installations and clearance distances from various site features. Distance on each side of meter needs to be covered n what are the materials that I can use being its temporary, On 2020-12-18 - by (mod) - Gas meter clearance to sources of ignition. On 2021-03-31 - by (mod) - required clearance of gas meter to fence or property line. ", @Marc, What does the laws take on this? The gas meter's label will indicate its capacity in cubic feet per hour (cf/h). Socalgas bill went from .64 cents a therm in November to $3.45 a therm in January. The published electrical clearances for gas meters are given in a table above titled found by searching InspectApedia.com for "mobile home codes" But your *local* building code compliance inspector is the final legal authority on clearance distances for gas (what - piping, meters, appliances?) Alberta Building Code You may also submit this application if your project involves replacing a SoCalGas meter with a larger capacity meter (meter upsize) due to the installation of additional natural gas appliances on your non-residential site. Maintaining the use of a wearless orbital valve, single convolution diaphragms, and lubrication-free bearings, the 400A delivers maximum initial and sustained accuracy. These Gas Meters Feature: Measures propane or natural gas in cubic feet. I feel its super unsafe and Im not running my heater until I find out. Sale. G as pi pi ng (ri ser, housel i ne fi tti ng) cannot be Gas meter clearance distance to domestic or residential water heater: You'll have to ask PG&E if your main gas service (line size and pressure) can accommodate your demands. All portions of a gas utility distribution system up to the outlet of the meter are regulated by 49 CFR Part 192, under the U.S. Department of Transportation. Southern California Gas Company is a subsidiary of Sempra. In that case the meter must be vented to the outdoors.Meters, when set inside, will be installed immediately such as a ventilation air opening. Las Cruces, New Mexico 88001 60332-G LOS ANGELES, CALIFORNIA CANCELING Revised CAL. 2019 Ardent Billing. - Source: ATCO, GAS METER CLEARANCE SPECIFICATIONS for ALBERTA [PDF] ATCO, ATCOenergy, ATCO Park : 5302 Forand Street S.W. 3 feet for non-utility gas meters and electric service equipment that can create an arc when operated. Justin The tables used to size gas piping are based on Cubic Feet per Hour (CF/H). The Alberta Gas Code Regulations, Gas Meter Clearances, BC, British Columbia, Canada, courtesy of Canadian Chimney, 521 Short Close Ladysmith, BC V9G 1A7 Canada, (250)800-2251 https://www.canadianchimney.com/, For BC, Canada gas meter clearances also see At lower altitudes, you might have a metered usage of 50 but billed for only 49.85 therms with a factor of 0.997. If the continuous meter capacity is greater than demand, your gas meters size is acceptable. Meter Technician (Former Employee) - San Luis Obispo, CA - March 17, 2022. The required clearances for equipment, vents, services, exhausts or openings to meter . Get information on the Advanced Meter technology and features. person disconnects the outlet of a gas service meter from the house piping , what must be done prior to turning on gas service meter ? Rule No. In a practical sense an OPINION might be, sufficiently separated so that no vibration or contact with sharp edges or materials could damage the gas line. When we connect solar to the grid or do a service upgrade they want us to comply most times, although a lot of time it is "grandfathered in" as well. Type of the property (Hotel, Take Away, Restaurant, Office etc) and type and numbers of the item which will use gas. Piping installed above ground, outdoors, and installed across the surface of roofs shall be securely supported and located where it will be protected from physical damage. The unthreaded portion of piping outlets shall extend not less than l inch (25 mm) through finished ceilings and walls and where extending through floors or outdoor patios and slabs, shall not be less than 2 inches (51 mm) above them. Those are needed. I feel like I am getting scammed or at least taken advantage of here. electric rates. high by 36 inches wide. You may also submit this application if your project involves converting from propane/electric to natural gas and/or your plans include building an accessory dwelling unit (ADU). Thanks for the discussion. Hose won't be able to connect. Agua Mansa Properties at 588 Agua Mansa Rd, Rialto CA 92376 - hours, address, map, directions, phone number, customer ratings and comments. Including to doorways. Any advice? That clear or grey box is the RF transmitted. Differential - Residential, 10.3" (262mm) wide, 10.0" (254mm) deep, and 15.0" (381mm) high - 425 CFH at 1/2" W.C. They also added what they are calling a meter calibration adjustment which upped ******** usage from 37 to 43. Brian I'd apply the clearance distance to all equipment since both safety and working space are requirements around the gas meter. (505) 476-4700 In a medium rise residential apartment building (17 stories) where the gas meter is installed in the ceiling may said meter be installed in an other than vertical position? The pictures are useful for utility checks, or when everyones usage and billing is reviewed. GilbertModel codes as well as your local building inspector will almost certainly require one or more protective bollards installed such that it becomes impossible to drive directly into the meter. I would be happy with that solution. I certainly find that a baffling claim myself. Let us know if you have more questions. (photo attached). It burns more efficiently at higher altitudes and less efficiently at lower altitudes. Boiler : 125. Refer to the following sections in the Natural Gas Service Guidebook to understand what youll need to know for your next residential new construction project: Get help to potentially save time and money on residential new construction projects. You can qualify for more than one baseline allocation addition, depending on the equipment. and electrical components (meter, service drop, etc). Rockwell International's predecessor was Rockwell Manufacturing Company, founded in 1919 by Willard Rockwell.In 1968, Rockwell Manufacturing Company . Thank You Dj. by inspectapedia.com.moderator (mod) I agree with you. GR rates are used to calculate your bill. A factory may use many thousands of kilowatts extra. Meter bases, conventional mechanical meters and conventional smart meters are not a source of ignition, and are permitted to be located within 1 metre of a natural gas discharge opening and 3 metres of a propane gas discharge opening. Indoor gas meter installations are generally not-recommended though local officials in your country-city may permit that. We will be very glad to help you. Our gas meter is three blocks from our house and there is a leak. Here is a sample of what our Southern California Gas breakdowns look like. Book your home inspection by calling 818-298-3405 or book online here. Here is the tricky part. Meters shall not be 23, Continuity of Service and Interruption of Delivery. The oven/stove, which I could convert to electric, and the central heat, which was just replaced three years ago. $12.95 Earn AQUAPOINTS In stock Add to Cart Dennerle Scaper's Tank Kit $163.20 $192.00 Save: $28.80 . Quoting from the AGA: PSE&G, "GAS APPLIANCE and GAS PIPING", [PDF], (2017), PSE&G Construction, New Jersey, USA, TEl: 800-722-0256, retrieved 2017/11/12, original source: https://www.pseg.com/business/builders/new_service/before/pdf/RequirementsGasService.pdf, PSE&G, "Gas Appliance and Gas Piping", [PDF], (2012), PSE&G Construction, New Jersey, USA, TEl: 800-722-0256, retrieved 4 June 2015, original source: https://www.pseg.com/business/builders/new_service/before/pdf/RequirementsGasService.pdf, Puget Sound Energy Inc's 2014 gas meter clearance specifications, retrieved 8/19/2014, - original source: https://pse.com/accountsandservices/Construction/Documents/3885.pdf, SOCAL, "Gas Service Guidebook", Southern California Gas Service Guidebook, [PDF] (2013) - original source: http://www.socalgas.com/documents/construction/GasServiceGuidebook.pdf, U.S. Energy Information Administration - eia.doe.gov/, U.S. Environmental Protection Agency - epa.gov/solar/energy-and-you/affect/natural-gas.html, At Natural Gas.Org www.naturalgas.org/environment/naturalgas.asp#emission youll find a table of combustion products, At geocities.com/rainforest/6847/report1.html is an interesting and detailed though not neutral report on the components and contaminants in the combustion of natural gas. Los Angeles, CA. Please attend a Public Participation Hearing (PPH) to provide the CPUC's Administrative Law Judge (Judge) with feedback as they oversee SoCalGas' 2024 General Rate Case (GRC) application for a rate increase. If you have the answers to the seven items mentioned above, you have what you need to select the correct regulator. The electrical conduit will intersect the gas line at a perpendicular angle. Or see GAS METER CLEARANCE DISTANCE FAQs - questions and answers posted originally on this page. Below are examples of ratings. @Christy, I need some answers. 192.353) (NFGC 5.7.2.3)Meters are to be located in ventilated spaces accessible I've seen lots of grills and other generators hooked up in the same fashion. A tracer wire. There are a number of instances in the CSA B149.1 Natural gas and Propane Installation Code house party melbourne / children's books about time, continuity, and change / children's books about time, continuity, and change Gas service line trench features are also described. Measure as a direct, straight line from the nearest meter set or component to the nearest edge of the building feature "as if using a string". See PG&E GREEN BOOK ELECTRIC & GAS SERVICE REQUIREMENTS (TD-7001M) 20202021 [PDF] original source: https://www.pge.com/pge_global/common/pdfs/services/building-and-renovation/greenbook-manual-online/greenbook_manual_full.pdf, Also see this oz. When the hand looks as though it is DIRECTLY on the number, look at the dial to the right. The standard daily rate is $0.16438 and the daily CARE rate is $0.131504. Tom and Jennie Tighe, Rossmoor residents since 1986, are irate that their gas bill went from $81 in December to a whopping $379 in . RE-posting from private email: Where passing through an outside wall, the piping shall also be protected against corrosion by coating or wrapping with an inert material. thanks. It also prohibits the gas meter reader to read it for billing purposes since you can't get in between the boat and the house to see it, nor is it shoveled. The house were renting has a gas line in the basement with 120 V cable sitting right on top of it??? With this specification met, there are no clearance distance requirements for building features located around the corner from the gas meter. 815 Agua Mansa Rd Bloomington, CA 92316 $12,500,000 4. You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response. -https://www.ecmag.com/section/codes-standards/code-questions-and-answers. The trademarks used herein are the property of their respective owners. More than likely, the cause of the squeaking noise is the internal parts of the gas meter rubbing against each other. Also if I increase the size of the gas meter, how big would it be? There is also misunderstanding about the term 'source of ignition.' To convert Btu/Hr to CF/H divide the Btu/Hr by 1,000 (per PG&E delivery capacity), which is the number of Btu/Hr in a single cubic foot of natural gas . The installation of the meter, regulator, house line and since in the event that the Amazon delivery truck rolls into the gas meter and sets off a gas leak and subsequent natural gas explosion, both homes and occupants could be in serious danger. Electrical panels, most electrical switches, relays, and similar controls that can create a spark when operated are considered a "source of ignition". Together, they produce a 4- or 5- digit reading. You may have heard about a CA Climate Credit for gas. Sign up and we'll send you blog updates and exclusive emails once or twice a month. 505 South Main Street, Suite 103 a 6 foot tall regulation cedar privacy fence is being built. The gas company may also want to inspect the installation. In this example, the number that appears after "Q max" is both the meter capacity and indicative of the meter size. Electric wiring and junction boxes, for instance, are not considered sources of ignition. Backfill must be free of sharp objects and must not contain rocks larger than 8", or increase sand shading depth to 12 inches. http://ww. @Tom Fuentes, ignition source, electrical panel or electrical meter. In general it is permitted to tap into the incoming gas line downstream from the gas meter provided that the work is done by a licensed plumber (or is permitted by others in your jurisdiction) and, of course, that the proper and safe devices and fittings are used. Using the "distance to sources of ignition" table in the article above I'd figure 3 ft. PLUS any additional working space required by either the meter or the water heater.Here's an excerpt;At least 3 feet, per NEC 110-26 & NFPA 54-National Fuel Gas Code for premises-owned gas meters. It is calculated based on the number of days in the billing cycle. These regulations require a three-foot clearance from indoor meters to sources of ignition, but have no comparable requirement when the meter is located outdoors. To keep things fair, each month the gas company assigns thermal factors to each region for how efficiently it burns. Permits for construction must be secured before completing this application.